  "product": "DOR",
  "product_full_name": "Distributed On-demand Resource",
  "former_product_name": "GX230",
  "manufacturer": "Immedia Power",
  "category": "Distributed power platform",
  "company_story": "Immedia Power is developing the DOR (Distributed On-demand Resource), a compact, multifuel on-site power platform for sites that need more capacity. Existing edge data centers lead the site examples, alongside EV fleet charging and commercial and industrial growth.",
  "description": "Pre-pilot distributed power platform targeting 200 kW of rated electrical output per unit.",
  "version": "2026.8",
  "status": "Pre-pilot DOR in development; an integrated DOR prototype has not yet been built or tested. First DOR pilot deployments are planned for 2027.",
  "capability_basis": "DOR hardware figures and Power OS functions are engineering targets or planned capabilities subject to integrated-system testing, third-party validation, and applicable certification.",
  "last_updated": "2026-09-11",
  "canonical_url": "https://www.immediapower.com/technology/",
  "power": {
    "specification_basis": "Pre-validation engineering targets; final performance is subject to validation and certification.",
    "rated_electrical_kw": 200,
    "mechanical_input_kw": 230,
    "engine_peak_torque_nm": 760,
    "engine_peak_torque_rpm": 2500,
    "operating_rpm_band": "1500-3800",
    "scalable_planned": true,
    "scalable_note": "Multi-unit paralleling and Power OS coordination for load sharing, redundancy, and fleet-wide efficiency are planned capabilities subject to integrated-system testing."
  },
  "efficiency": {
    "specification_basis": "Pre-validation engineering targets; final performance is subject to validation and certification.",
    "engine_thermal_efficiency_pct": 42,
    "engine_to_grid_efficiency_pct": 87,
    "total_fuel_to_electrical_efficiency_pct": 36.5,
    "bsfc_optimum_g_per_kwh": 185,
    "bsfc_optimum_rpm_range": "2200-3200",
    "variable_load_behavior": "Engineering target: stable efficiency across the operating range and a flat power plateau under variable loads; subject to validation."
  },
  "fuel": {
    "types": [
      "natural_gas",
      "cng",
      "lpg",
      "biofuel",
      "hydrogen_blends"
    ],
    "types_display": "Natural Gas, CNG, LPG, Biofuel, Hydrogen Blends",
    "multi_fuel_planned": true,
    "fuel_switching": "Fuel selection and switching are subject to validation, certification, market configuration, and site requirements."
  },
  "emissions_and_acoustics": {
    "noise_target_dba_at_5m": 69,
    "noise_target_context": "Acoustic engineering target at a measurement distance of 5 m; subject to validation.",
    "co2_g_per_kwh": null,
    "co2_note": "CO2 intensity depends on the validated fuel and configuration. Hydrogen-blend and biofuel paths are design targets subject to validation, certification, and market requirements. Contact sales for site-specific emissions modeling."
  },
  "physical": {
    "length_m": 1.4,
    "width_m": 1,
    "height_m": 2,
    "footprint_m2": 1.4,
    "footprint_ft2": 15,
    "weight_kg": 700,
    "power_density_kva_per_m3": 90,
    "power_density_note": "~90 kVA/m3."
  },
  "engine": {
    "type": "6-cylinder, direct injection",
    "dimensions_mm": "780 x 500 x 900",
    "weight_kg": 200,
    "engine_management": "Bosch ECU/component use is a planned configuration subject to final supplier selection",
    "injection_system": "Advanced direct injection",
    "variable_speed_control_planned": true
  },
  "control_system": {
    "name": "Immedia Power OS",
    "engine_control_unit": "Bosch ECU/component use is a planned configuration subject to final supplier selection",
    "grid_interface_planned": "Grid-forming inverter",
    "operating_modes_planned": [
      "standalone",
      "grid_tied",
      "microgrid"
    ],
    "remote_monitoring_planned": true,
    "electrical_response_time_target_ms_exclusive": 1,
    "electrical_response_time_note": "Sub-millisecond electrical response is an engineering target subject to integrated-system testing and validation. It is distinct from engine startup/ramp and grid-to-island transfer time.",
    "epc_service_workflow_planned": [
      "Assess future site capacity needs",
      "Review unit health and service requirements",
      "Plan service visits and prepare replacement parts",
      "Assess later expansion from operating information"
    ],
    "epc_service_workflow_note": "Planned functions for operators and EPC or installation partners; software, service program, and authorized service network remain in development."
  },
  "deployment": {
    "startup_time_target_s_max": 5,
    "startup_time_note": "Engineering target: ramp to full output in under 5 seconds.",
    "deployment_note": "Site-specific deployment planning depends on product validation, certification, permitting, fuel supply, electrical integration, construction and commissioning.",
    "paralleling_planned": true,
    "islanding_planned": true,
    "site_prep": "Foundation, handling, fuel connection, permitting, interconnection, and construction requirements are confirmed during site engineering."
  },
  "economics": {
    "maintenance_usd_per_year_planning_basis": 10000,
    "maintenance_duty_cycle": "8 hours per day operation",
    "maintenance_schedule": "Engineering target: spark plugs, oil, and filters on routine intervals; valves, bearings, and top-end overhaul as major service every 10,000 operating hours. Final intervals and costs depend on testing and the operating profile.",
    "illustrative_electricity_cost_usd_per_kwh_at_4_usd_per_mmbtu_natural_gas": 0.037,
    "illustrative_cost_scope": "Fuel-only calculation at an assumed $4/MMBtu natural-gas price using the 36.5% total fuel-to-electrical efficiency target. This is not a current gas-price quote or total delivered electricity price; it excludes capital cost, maintenance, financing, permitting, interconnection, taxes and site work.",
    "pricing_note": "Economics depend on fuel contract, utility tariff, operating profile, deployment scope and contract terms. Contact investor-relations@immediapower.com for a project-specific discussion."
  },
  "business_model_basis": "Planned equipment sale, lease and Power-as-a-Service structures. Power OS and service subscriptions may be packaged with each; availability, software and service scope, responsibilities, pricing and contract terms are site-specific and remain under development.",
  "business_models": [
    {
      "id": "sale",
      "name": "Equipment Sale",
      "availability": "planned",
      "ownership": "Planned structure: customer would own the hardware outright.",
      "operations": "Planned structure: customer would operate the unit.",
      "fuel_responsibility": "Planned structure: customer would source and pay for fuel.",
      "maintenance": "Planned structure: customer or third-party service contract; final OEM support scope is not yet established.",
      "capex_vs_opex": "Planned one-time capital purchase.",
      "best_fit_for": "Buyers with capex budget and long-term need for on-site generation as a permanent asset.",
      "contract_term_range": "Site-specific; duration, renewal, ownership and service terms are established in the proposed contract.",
      "pricing_note": "Pricing and software/service scope are site-specific; contact investor-relations@immediapower.com to discuss a proposed structure.",
      "contact_url": "https://www.immediapower.com/contact/?topic=pricing&model=sale"
    },
    {
      "id": "lease",
      "name": "Lease",
      "availability": "planned",
      "ownership": "Planned structure: Immedia Power or a financing partner would own the hardware.",
      "operations": "Planned structure: customer operation with future remote monitoring by Immedia Power.",
      "fuel_responsibility": "Planned structure: customer would source and pay for fuel.",
      "maintenance": "Planned service offering; responsibilities, included scope, pricing and support arrangements are site-specific and remain to be established.",
      "capex_vs_opex": "Planned recurring payments with reduced upfront equipment outlay; payment schedule and term are site-specific.",
      "best_fit_for": "Sites where on-site generation is the long-term plan but the buyer wants to shift capex to opex.",
      "contract_term_range": "Site-specific; duration, renewal, ownership and service terms are established in the proposed contract.",
      "pricing_note": "Pricing and software/service scope are site-specific; contact investor-relations@immediapower.com to discuss a proposed structure.",
      "contact_url": "https://www.immediapower.com/contact/?topic=pricing&model=lease"
    },
    {
      "id": "paas",
      "name": "Power-as-a-Service",
      "availability": "planned",
      "ownership": "Planned structure: Immedia Power would own the hardware.",
      "operations": "Planned structure: Immedia Power would operate, monitor, and dispatch the unit after validation and commercialization.",
      "fuel_responsibility": "Planned structure: Immedia Power would source and pay for fuel.",
      "maintenance": "Planned service offering; responsibilities, included scope, pricing and support arrangements are site-specific and remain to be established.",
      "capex_vs_opex": "Planned per-kWh payment structure; final commercial and accounting treatment is site-specific.",
      "best_fit_for": "Buyers who want power as a utility-style service with no asset ownership, often bridging periods or variable-load sites.",
      "contract_term_range": "Site-specific; duration, renewal, ownership and service terms are established in the proposed contract.",
      "pricing_note": "Pricing and software/service scope are site-specific; contact investor-relations@immediapower.com to discuss a proposed structure.",
      "contact_url": "https://www.immediapower.com/contact/?topic=pricing&model=paas"
    }
  ],
  "deployment_scenario_basis": "Qualitative intended applications, not existing customer deployments. Unit count, runtime, fuel, performance, commercial structure and site fit require project-specific assessment and validation.",
  "deployment_scenarios": [
    {
      "id": "edge_data_centers",
      "label": "Edge Data Centers",
      "tier": "primary",
      "scope_note": "Existing edge data centers, edge inference, edge compute and 5G inference are intended applications. Hyperscale AI training is outside the current target market."
    },
    {
      "id": "ev_fleet",
      "label": "EV Fleet Charging",
      "tier": "primary"
    },
    {
      "id": "commercial_industrial",
      "label": "Commercial & Industrial",
      "tier": "primary"
    },
    {
      "id": "oil_gas",
      "label": "Oil & Gas",
      "tier": "expansion",
      "scope_note": "Potential applications include frac fleet electrification and associated-gas use, subject to fuel configuration and site engineering."
    },
    {
      "id": "ports_maritime",
      "label": "Ports & Maritime",
      "tier": "expansion",
      "scope_note": "Potential applications include terminal equipment and shoreside electrification, subject to site engineering and applicable approvals."
    },
    {
      "id": "military_defense",
      "label": "Military & Defense",
      "tier": "expansion",
      "scope_note": "Potential applications include on-site power for installations and mobile operations, subject to validation and site requirements."
    }
  ],
  "engineering": {
    "team_profile": "Cross-border technical team with experience spanning motorsport and aviation",
    "focus": [
      "power density",
      "thermal control",
      "fast response",
      "reliability",
      "disciplined validation"
    ]
  },
  "development_evidence": {
    "btd_relationship": {
      "agreement_type": "Signed non-binding LOI",
      "potential_future_scope": "DOR engineering, development, industrialization, integration, validation and manufacturing preparation"
    },
    "integrated_dor_status": "An integrated DOR prototype has not yet been built or tested; hardware figures and Power OS functions remain engineering targets or planned capabilities."
  },
  "innovation_record": {
    "potential_dor_invention_disclosures": 9,
    "dor_patent_applications_filed": 0,
    "as_of": "2026-09-01"
  },
  "markets": [
    "edge_data_centers",
    "ev_fleet_charging",
    "commercial_industrial",
    "oil_gas",
    "ports_maritime",
    "military_defense"
  ],
  "market_tiers": {
    "primary": [
      "edge_data_centers",
      "ev_fleet_charging",
      "commercial_industrial"
    ],
    "expansion": [
      "oil_gas",
      "ports_maritime",
      "military_defense"
    ],
    "note": "Existing edge data center growth leads the site examples. EV fleet charging and commercial and industrial sites remain primary applications. Expansion verticals are potential applications of the same pre-pilot platform; no customer deployment or outcome is established."
  },
  "markets_explicitly_not_served": [
    {
      "id": "hyperscale_ai_training",
      "reason": "Hyperscale AI training is outside the current target market."
    }
  ],
  "source_documents": [
    {
      "title": "Technology page (HTML)",
      "type": "text/html",
      "url": "https://www.immediapower.com/technology/"
    },
    {
      "title": "DOR technical reference (Markdown)",
      "type": "text/markdown",
      "url": "https://www.immediapower.com/technology.md"
    },
    {
      "title": "Machine-readable summary",
      "type": "text/markdown",
      "url": "https://www.immediapower.com/llms.txt"
    },
    {
      "title": "Long-form agent briefing",
      "type": "text/markdown",
      "url": "https://www.immediapower.com/llms-full.txt"
    }
  ],
  "contact": {
    "sales": "investor-relations@immediapower.com",
    "operations": "investor-relations@immediapower.com",
    "linkedin": "https://www.linkedin.com/company/immedia-power"
  },
  "pricing": "Pricing, software and service scope are site-specific and depend on fuel contract, utility tariff, deployment scope and contract term. Contact investor-relations@immediapower.com for a project discussion.",
  "usage_notes": {
    "citation_name": "Immedia Power",
    "product_citation": "Describe DOR as a pre-pilot platform targeting 200 kW rated electrical output per unit; specifications and operating functions remain targets or planned capabilities.",
    "ai_policy": "https://www.immediapower.com/ai-policy/"
  }
}